Photometric Plan Analysis Study Miami Dade / Cost

Photometric for measurements for Parking Lot Illumination, Cost starts at $600 in Miami Beach, Dade, Hialeah, Coral Gables, Homestead, Doral, Broward County.

786-318-7203 / info@allhomemeters.com

Photometric Plan Miami Dade Study Survey Drawings Parking Lot Illumination Beach Hialeah Doral Coral Gables.

Professional Engineers inspecting Parking Lot Lighting / Illumination for 30/40 Year Recertification and performing photometric studies, LED lighting design, light fixtures analysis, study lighting solutions, photometric plan lighting project, lighting layout of led lights, wall packs, flood lights, LED lighting, high bays, canopy lights, etc.

Photometric Plans, Studies Parking Lot Survey Dade, Hialeah, Broward County, Homestead, Coral Gables, Doral, Fort Lauderdale, Hollywood, Florida, LED Lighting Design.

Sec. 8C-3. - Illumination for open parking lots, alleys and access thereto and parking and nonenclosed areas under or within buildings, Photometric Study Analysis Lighting.

(a) Generally:

(1) This Dade County Section applies to new construction and all existing buildings.

(2) Open parking lots, alleys, and access thereto shall be illuminated as set forth below. For purposes of this paragraph, alley is defined as a narrow vehicular thoroughfare up to twenty-five (25) feet in width upon which service entrances or buildings abut and not generally used as a thoroughfare for general traffic; provided, however, alleys shall not include public rights-of-way.

(b) Groups A (Assembly), D (Day Care) and E (Educational) occupancies:

(1) Open parking lot and access thereto shall be provided with a maintained minimum of 1 foot-candle on the parking surface from dusk until dawn; provided, however, the light levels may be reduced by fifty (50) percent on non-business days and commencing thirty (30) minutes after the termination of business on each operating day. The uniformity ratio shall not exceed a twelve to one ratio (12:1) maximum to minimum. This provision shall not apply to governmental facilities not generally open to the public, and shall apply to those governmental facilities that are generally open to the public only during the dusk-to-dawn hours such facilities are open.

(2) Parking and nonenclosed areas under or within buildings at grade shall be provided with a maintained minimum of 1 foot-candle of light on the parking and walking surfaces from dusk until dawn and the ratio of maximum to minimum illumination shall not exceed twelve to one (12:1); provided, however, the light levels may be reduced by fifty (50) percent on non-business days and thirty (30) minutes after the termination of business one each operating day. This provision shall not apply to governmental facilities not generally open to the public, and shall apply to those governmental facilities that are generally open to the public only during the dusk-to-dawn hours such facilities are open.

(3) Alleys shall be provided with a maintained minimum of 1/3 foot-candle on the alley surface from dusk to dawn. The uniformity ratio shall not exceed a twelve to one (12:1) maximum to minimum. This provision shall not apply to governmental facilities not generally open to the public, and shall apply to those governmental facilities that are generally open to the public only during the dusk-to-dawn hours such facilities are open.

(c) Groups F (Factory Industrial), H (Hazardous), I (Institutional), S (Storage) and R4 (Residential care/assisted living facilities) occupancies:

(1) Open parking lot and access thereto shall be provided with a maintained minimum of 0.5 foot-candle on the parking surface from dusk until dawn; provided, however, the lighting level may be reduced by fifty (50) percent on non-business days and commencing thirty (30) minutes after the termination of business on each operating day. The uniformity ratio shall not exceed a twelve to one ratio (12:1) maximum to minimum foot-candles.

(2) Alleys shall be provided with a maintained minimum of 1/3 foot-candle on the alley surface from dusk to dawn. The uniformity ratio shall not exceed a twelve to one (12:1) maximum to minimum foot-candles. This provision shall not apply to governmental facilities not generally open to the public, and shall apply to those governmental facilities that are generally open to the public only during the dusk-to-dawn hours such facilities are open.

(3) Parking and nonenclosed areas under or within buildings at grade shall be provided with a maintained minimum of 1 foot-candle of light on the parking and walking surfaces from dusk until dawn and the ratio of maximum to minimum illumination in foot-candles shall not exceed twelve to one (12:1) provided, however, the light levels may be reduced by fifty (50) percent on non-business days and commencing thirty (30) minutes after the termination of business on each operating day. This provision shall not apply to governmental facilities not generally open to the public, and shall apply to those governmental facilities that are generally open to the public only during the dusk-to-dawn hours such facilities are open.

(4) The area immediately outside of exterior doors shall have security illumination and shall be activated during the dark period of every day.

(d) Group B (Business) and M (Mercantile) occupancies:

(1) Open parking lot and access thereto shall be provided with a maintained minimum of 1.0 foot-candle on the parking surface from dusk until dawn; provided, however, the level may be reduced by fifty (50) percent on non-business days and commencing thirty (30) minutes after the termination of business on each operating day. The uniformity ratio shall not exceed a twelve to one ratio (12:1) maximum to minimum foot-candles.

(2) Alleys shall be provided with a maintained minimum of 1/3 foot-candle on the alley surface from dusk to dawn. The uniformity ratio shall not exceed a twelve to one (12:1) maximum to minimum foot-candles. This provision shall not apply to governmental facilities not generally open to the public, and shall apply to those governmental facilities that are generally open to the public only during the dusk-to-dawn hours such facilities are open.

(3) Parking and nonenclosed areas under, or within buildings shall be provided with a maintained minimum of 1 foot-candle of light on the walking and parking surfaces from dusk until dawn, and the ratio of maximum to minimum illumination in foot-candles shall not exceed twelve to one (12:1); provided, however, the level may be reduced by fifty (50) percent on non-business days and commencing thirty (30) minutes after the termination of business on each operating day. It is provided, however, that this provision shall not apply to governmental facilities not generally open to the public, and shall apply to those governmental facilities that are generally open to the public only during the dusk-to-dawn hours such facilities are open.

(4) The area immediately outside of exterior doors shall have security illumination and shall be activated during the dark period of every day.

(e) Group R1 (Residential transient) and R2 (Residential multiple dwelling) occupancies:

(1) Open parking lot and access thereto shall be provided with a maintained minimum of 1.0 foot-candle on the parking surface from dusk until dawn. The uniformity ratio shall not exceed a twelve to one ratio (12:1) maximum to minimum foot-candles. Alleys shall be provided with a maintained minimum of one-third ( 1/3 ) on the alley surface from dusk to dawn.

(2) Parking and nonenclosed areas under, or within buildings shall be provided with a maintained minimum of 1.0 foot-candle of light on the walking and parking surfaces from dusk until dawn, and the ratio of maximum to minimum illumination in foot-candles shall not exceed twelve to one (12:1).

(Miami Dade County Ord. No. 01-196, ยง 1, 11-20-01)

Contact us for your Photometric Analysis Lighting Plan Study.

Photometric Study Plan Hialeah, Parking Illumination Fort Lauderdale by the Sea, Coral Gables, Homestead, Kendall West, Kendale Lakes, The Hammocks, Aventura, Bal Harbour, Bay Harbor Islands, Key Byscayne, Biscayne Park, Cutler Bay, Doral, El Portal, Photometric Plan Florida City, Golden Beach, Indian Creek, Medley, North Bay Village, Opa-Locka, Palmetto Bay, Pinecrest, Sunny Isles Beach, Surfside, Sweetwater, Virginia Gardens, Coconut Creek, Photometric Plan Cooper City, Coral Springs, Dania Beach, Davie, Deerfield Beach, Hallandale Beach, Hillsboro Beach, Hillsboro Pines, Hollywood, Lauderhill, Lighthouse Point, Margate, Miramar, Photometric Plan Oakland Park, Parkland, Photometric Plan Pembroke Pines, Pembroke Park, Plantation, Pompano Beach, Sea Ranch Lakes, Southwest Ranches, Sunrise, Photometric Plan Tamarac, West Park, Weston, Wilton Manors, Brownville, Calusa Club, Coral Terrace, Country Club, Allapattah, Coconut Grove, Liberty City, Little Havana, Wynwood, Country Walk, Fisher Island, Fontainebleau, Gladeview, Glenvar Heights, Golden Glades, Goulds, Ives Estates, Leisure City, Naranja, Ojus, Olympia Heights, Little Haiti, Design District, Palm Springs North, Palmetto Estates, Pinewood, Princeton, Richmond Heights, Richmond West, Sunset, Tamiami, The Crossings, Home Services Three Lakes, University Park, West Little River, Perrine, Photometric Plan Westchester, Westview, Westwood Lakes, Andover, Bunche Park, Carol City, Coral Way Village, Dadeland, Green-Mar Acres, Hawlwy Heights, Howard, Lake Lucerne, Norwood, Saga Bay, Scott Lake, Boulevard Gardens, Broadview Park.

For Photometric Analysis Plan / Lighting - Call 786-318-7203.